Vedere la pagina 74
Drive Bay Installation/Removal
007-5688-001 53
Replacing System Fans
This section describes how to remove or install a system fan.
Removing a Fan
1. Remove the chassis cover.
2. Press the tabs on the sides of the fan to unlock and remove the fan and its housing. The fan's
power connections will automatically detach.
3. System power does not need to be shut down since the fans are hot-pluggable.
Installing a New Fan
1. Replace the failed fan with an identical 8-cm, 12 volt fan.
2. Position the new fan into the space vacated by the failed fan previously removed. A "click"
can be heard when the fan is fully installed in place and the power connections are made.
3. If the system power is on, the hot-plug feature will cause the fan to start immediately upon
being connected to its header on the serverboard.
Drive Bay Installation/Removal
This section describes drive bay installation and removal.
Accessing the Drive Bays
SATA Drives: You do not need to access the inside of the chassis or remove power to replace or
swap SATA drives. Proceed to the next step for instructions.
Note: You must use standard 1" high, SATA drives in the system.
DVD-ROM Drive: For installing/removing the DVD-ROM disk drive, you will need to gain
access to the inside of the server by removing the top cover of the chassis. Proceed to the
"DVD-ROM Drive Installation" section later in this chapter for instructions.